Product Details:
Brand | Adarsh International |
Material | Mild Steel |
Phase | Single Phase |
Power | 40 kW |
Voltage | 240 V |
Usage/Application | Laboratory |
Product Details:
Brand | Adarsh International |
Usage/Application | Laboratory |
Material | Mild Steel |
Phase | Single Phase |
Frequency | 50 Hz |
Voltage | 240 V |
Product Details:
Brand | Adarsh International |
Usage/Application | Laboratory |
Material | Stainless Steel |
Phase | Single Phase |
Heating Temperature | 40-80 Deg C |
Voltage | 220 V |
Power Source | Electric |
The apparatus consists of a variable speed D.C. Motor, Driving pulley and Driven pulley of equal diameter. The pulleys are mounted on input shaft (Motor shaft) and output shaft. The driven pulley can slide on the base with bearing block to change initial tension in belt. Brake drum is mounted on output shaft helps to measure power output. The motor speed is varied by dimmerstat. A two channel RPM Indicator is provided to measure speeds of driven and driving pullies respectively.
Product Details:
Usage | Laboratory |
Material | Mild Steel |
Power Supply | Electric |
Input Voltage | 230 V |
Brand | Adarsh International |
Frequency | 50-60 Hz |
Product Details:
Usage | Laboratory |
Type | Electrical |
Material | Stainless Steel |
Input Voltage | 230 V |
Brand | Adarsh International |
Frequency | 50-60 Hz |
Product Details:
Usage | Laboratory |
Type | Electrical |
Material | Mild Steel |
Input Voltage | 240 V |
Brand | Adarsh International |
Phase | 3 Phase |
Product Details:
Minimum Order Quantity | 1 Unit |
Material | SS,MS,Plastic |
Usage | Thermodynamics Lab |
Brand | Adarsh International |
Project Subject | Thermodynamics |
Additional Information:
Product Details:
Minimum Order Quantity | 1 Set |
Brand | Adarsh International |
Material | SS,MS,Plastic |
Automation Type | Semi-Automatic |
Usage/Application | Refrigeration & AC Lab |
The Air Conditioning Equipment Test Rig unit is required to conduct experiments and demonstrate the process of cooling of atmospheric air.
The self contained unit will be fitted with all of instruments facilities so that is temperature, pressure etc. may be measured at different points in the air conditioning system.
Additional Information:
Product Details:
Project Subject | Theory of Machine Lab |
Brand | Adarsh International |
Suitable For | Teaching |
Material | SS,MS,Wood |
Product Details:
Material | Mild Steel |
Usage/Application | Laboratory |
Bend Elbow Size | 1/2 inch |
Ball Valve Size | 15 to 25 mm |
Voltage | 220 V |
Brand | Adarsh International |
The Set-up consists of a bend and elbow, a sudden expansion & sudden contraction fitting from, ball valve and gate valve. Pressure tapings are provided at inlet and outlet of these fittings under test. A differential manometer fitted in the line gives pressure loss of individual fitting. Present Set-up is self-contained water re-circulating unit, provided with a sump tank and a centrifugal pump etc. Flow control valve and by-pass valve are fitted in water line to conduct the experiment on different flow rates. Flow rate of water is measured with the help of measuring tank and stop watch.
Product Details:
Brand | Adarsh International |
Usage/Application | Laboratory |
Material | Mild Steel |
Voltage | 240 V |
Surface Finish | Paint Coated |
Product Details:
Material | MS |
Usage/Application | Laboratory |
Surface Finish | Color Coated |
Brand | Adarsh International |
Voltae | 240 V |
Product Details:
Usage/Application | Laboratory |
Voltage | 220 V |
Heating Temperature | 50 to 120 Deg C |
Brand | Adarsh International |
Product Details:
Usage/Application | Laboratory |
Voltage | 220 V |
Frequency | 50-60 Hz |
Speed | 450 rpm |
Brand | Adarsh International |
Product Details:
Material | Mild Steel |
Usage/Application | Laboratory |
Voltage | 240 V |
Frequency | 50 Hz |
Brand | Adarsh International |
The test rig comprises of a two-stage air compressor fitted with an air tank with orifice, pressure gauges 9 an energy meter to measure the input & a Temperature indicator measures the temperatures at various points. The compressor is mounted on air receiver along with the motor, and is provided with air relief valve (safety) and a pressure switch. The unit determines volumetric efficiency and isothermal efficiency at various discharge pressures.
Product Details:
Usage/Application | Laboratory |
Voltage | 230 V |
Pressure | 70-110 Bar |
Temperature | 20-40 Deg. C |
Brand | Adarsh International |
Product Details:
Usage/Application | Laboratory |
Power Source | Electric |
Voltage | 220 V |
Brand | Adarsh International |
Frequency | 50-60 Hz |
Product Details:
Application | Laboratory Use |
Brand | Adarsh International |
Phase | 3 Phase |
Power Source | Electric |
Voltage | 230 V |
Product Details:
Usage/Application | Laboratory |
Voltage | 240 V |
Frequency | 50-60 Hz |
Surface Finish | Paint Coated |
Brand | Adarsh International |
The unit consists of a main spindle driven by a variable speed motor. Three different governor assemblies can be mounted over the spindle. A with pointer measures the lift of the governor. Students can calculate characteristics of governor at and compare their performance viz. Sensitiveness, stability, governor effort etc.
Product Details:
Application | Laboratory |
Frequency | 50 Hz |
Motor Power | 0.5 HP |
Voltage | 220 V |
Power Source | Electric |
Product Details:
Usage/Application | Laboratory |
Operating Voltage | 220 V |
Brand | Adarsh International |
Body Material | Mild Steel |
Temperature | 50-140 Deg C |
Product Details:
Usage/Application | Laboratory |
Operating Voltage | 220 V |
Surface Finish | Paint Coated |
Body Material | MS |
Frequency | 50-60 Hz |
Product Details:
Minimum Order Quantity | 1 Set |
Usage/Application | Heat Transfer Lab |
Brand | Adarsh International |
Material | Plastic,SS,MS |
Medium Used | Air,Oil,Water |
Additional Information:
Product Details:
Minimum Order Quantity | 1 Piece |
Brand | Adarsh International |
Usage/Application | Fluid Mechanics Lab |
Material | MS,SS,Plastic |
Automation Type | Semi-Automatic |
Fluid Mechanics Lab Equipment Flow Through Orifice and Mouthpiece Pitot Tube Setup Reynold Apparatus Jet Pump Test Rig Flow Over Notch Metacentric Heightbernoull''s Theorem Apparatus Venturi Meter And Orifice Meter Apparatus Impact Of Jet Of Vane.
Additional Information:
4.2/5
Reviewed by 157 Users
Most Relevant Reviews
Response from Seller (26-February-21)
Thank you for the rating. We will always strive to live upto your expectations and deliver the best.
Response from Seller (16-December-21)
Thank you for the rating. We will always strive to live upto your expectations and deliver the best.